Antenna discharge units shall be located outside the building or inside the building between the point of entrance of the lead-in and the radio set or transformers and as near as practicable to the entrance of the conductors to the building. The antenna discharge unit shall not be located near combustible material or in a hazardous (classified) location as defined in Article 500.
Show more
See More
Nov 02, 2006 . An antenna-discharge unit - hereinafter referred to as a discharge unit - as covered by these requirements consists of a gap, a fixed resistance or other discharge element, or a combination of such features, connected between each antenna lead-in terminal and a grounding terminal.
Show more
See More
Mar 07, 2014 . UL standard UL 452 covers antenna discharge units. However, at this time (December 2011) there are only three manufacturers that make listed products according to UL 452, and there are no devices that have specific radio amateur applications.
Show more
See More
"The antenna discharge unit (also called a “lightning arrestor”) is connected to the transmission line at a point close to where the transmission line enters the house" So we should install both the grounding block and lightning arrestor near the place where the coax enters the house....
Show more
See More
The TV antenna discharge unit (also called a "lightning arrestor") is connected to the transmission line at a point close to where the transmission line enters the house. One end of a ground wire is attached to the discharge unit. The other end of the wire is connected directly to the ground rod.
Show more
See More
Use either a listed grounding block, which simply grounds the shield (more than sufficient), or a listed antenna discharge unit (which grounds the shield and also adds a lightning arrester for the center conductor). Secure the grounding block to the structure with screws, then screw on the coax cables to both sides.
Show more
See More
Jan 05, 2009 . building between the point of entrance of the lead-in and the radio set or transformers and. as near as practicable to the entrance of the conductors to the building. The antenna. discharge unit shall not be located near combustible material or in …
Show more
See More
TV antenna transmission lines can develop a buildup of static electricity that acts as a magnet for lightning strikes. Static discharge is a big concern in the southwest where humidity is low, and in northern areas where indoor heaters create low humidity in the winter. An antenna discharge unit decreases these risks.
Show more
See More
Show more
See More
Dec 24, 2019 . Just put a 10k resistor over the antenna terminal inside the receiver. It will bleed off any static build ups due to the climate and weather. The gas arrestors and other things you mention are for lightning protection, not static build up.
Show more
See More
A box discharge unit can empty drop bottom waste boxes. Esta unidad puede vaciar c ontenedores de des echos con descarga inferior. [...] has been found for the omni-directi onal antenna and for the base unit, the antenna shou ld be mounted and cable connected to the antenna and to the base unit.
Show more
See More
Mar 03, 2002 . The discharge unit must be grounded to an acceptable location in accordance with 810.21(F)(1)(a) through (f), with a 10 AWG copper conductor (bare or insulated) that is run in as straight a line as practicable [810.21(E)] to the electrode.
Show more
See More
The antenna discharge unit is not to be located near combustible material and certainly not within a hazardous (classified) location. The antenna discharge unit must be grounded. The grounding conductor is usually copper; however, you can use aluminum or copper-clad aluminum if it’s not in contact with masonry or earth.
There is no antenna discharge unit as required for satellite dish installation. Instead, the shield of the coaxial cable is connected to an insulated grounding conductor that is limited to copper but may be stranded or solid.
The grounding conductor can be bare or insulated, stranded or solid, and must be securely fastened in place and run in a straight line from the discharge unit to the grounding electrode (Photo 2). If the building has an intersystem bonding termination, the grounding conductor is to be connected to it or to one of the following: