Instruction Manuals CAMAG® Automatic TLC Sampler 4 (ATS 4) pdf. CAMAG® Linomat 5. pdf. CAMAG® AMD 2 System Automated Multiple Development. pdf. CAMAG® Automatic Developing Chamber 2 (ADC 2) pdf. CAMAG® Derivatizer. pdf. CAMAG® TLC Scanner 4. pdf. CAMAG® TLC Visualizer 2. pdf. CAMAG® TLC-MS Interface 2. pdf.
Show more
See More
This video tutorial shows the manual plate loading, the application process steps and the development process steps including the automated transport from on...
Show more
See More
CAMAG® Linomat 5 With the Linomat 5 samples are sprayed onto TLC/HPTLC plates in the form of bands with nitrogen or compressed air. Application is automatic, only changing the syringe (filling, inserting and rinsing) is manual.
Show more
See More
TLC-MS coupling allows for verification of the chemical structure of analytes by Mass Spectrometry. Analytes can be directly eluted to an MS or the eluate can be collected for further analysis offline. More about this process step. /product/CAMAG-tlc-ms-interface-2. CAMAG® TLC-MS Interface 2.
Show more
See More
For customers working in a cGMP/cGLP environment, CAMAG offers Installation Qualification (IQ) and Operation Qualification (OQ) services. System Suitability Test (SST) System Suitability Tests are used on each plate to check and ensure that the analysis was performed appropriately to produce results that are within the acceptance criteria established during method development.
Show more
See More
HPTLC chromatograms are captured images of the plates under white or ultraviolet light. For electronic image acquisition a digital camera captures visible polychromatic light. The obtained data can be edited, archived and evaluated. For quantitation densitograms or …
Show more
See More
The fully automated CAMAG DBS-MS extraction system makes DBS analysis remarkably easy and has strong advantages compared to both, the manual and semi-automated punching techniques. With the CAMAG DBS-MS 500 HCT extraction procedure, DBS analysis is an economical alternative to conventional blood sampling.
Show more
See More
CAMAG, the world’s pioneer and leader in HP-TLC software and instrumentation researched and designed instruments to take advantage of all above unique aspects. CAMAG, manufactures in Switzerland manual, semi-automatic, automatic and recently completely automatic software controlled HPTLC Systems and certain special accessories like HPTLC-MS, Gradient Chamber, Method …
Show more
See More
This video tutorial shows the manual loading of an HPTLC glass plate to the HPTLC PRO Module APPLICATION and the unloading of the plate from the HPTLC PRO Mo...
Show more
See More
The TLC-MS Interface 2 enables users to directly analyze zones from TLC and HPTLC plates by Mass Spectrometry. A substance confirmation can be obtained in less than a minute. The elution-based TLC-MS Interface 2 is a highly convenient and versatile instrument allowing for rapid and contamination...
Show more
See More
The CAMAG Derivatizer sets a new standard of reproducibility and convenience in reagent transfer onto TLC/HPTLC plates by employing a unique “micro droplet” spraying technology (patent pending). ... the Derivatizer offers other advantages as compared to manual spraying. Environmentally friendly and safe handling through a closed system.
Show more
See More
CAMAG, manufactures in Switzerland manual, semi-automatic, automatic and recently completely automatic software controlled HPTLC Systems and certain special accessories like HPTLC-MS, Gradient Chamber, Method Development Chamber, Bioluminizer.
The software organizes the workflow of HPTLC, controls the involved CAMAG® HPTLC PRO Modules and CAMAG® instruments, and manages data. The easy to navigate user interface effectively guides the user through the chromatographic process – from definition of samples and substances to reporting of results.
For customers working in a cGMP/cGLP environment, CAMAG offers Installation Qualification (IQ) and Operation Qualification (OQ) services. System Suitability Tests are used on each plate to check and ensure that the analysis was performed appropriately to produce results that are within the acceptance criteria established during method development.
Scanner operation with winCATS software is convenient and easy to learn. The object, here a 20 × 10 cm HPTLC plate, is simply positioned on the scanning table. The coordinates are displayed during manual positioning of the stage and can be transfer- red into the program by mouse-click.