Page 30 , Femtochrome shall in no way be liable for damages consequential or incidental to defects in any of the products, for injuries resulting from its use, or for any other cause. This limited warranty constitutes the full understanding of Femtochrome and the buyer, and no...
Show more
See More
Femtochrome Manuals Femtochrome FR-103MN Download Instruction manual of Femtochrome FR-103MN Measuring Instruments for Free or View it Online on All-Guides.com.
Show more
See More
Femtochrome offers dispersion-free, 'real-time' autocorrelators with. Dynamic Range → 10 4. Sensitivity: (P av P pk) min → 10-7 W 2. Resolution → 1fs ... Wide Scan Ranges w/ 1fs resolution ... Ultimate Accuracy (user verifiable calibration)These unsurpassed specifications facilitate measuring
Show more
See More
User Manuals, Guides and Specifications for your H2flow FV-8 Measuring Instruments. Database contains 1 H2flow FV-8 Manuals (available for free online viewing or downloading in PDF): Operating manual . ... Femtochrome FR-103MN Instruction Manual Instruction manual (30 pages) Keller LEO 2 Manual Manual (8 pages) Keller LEO1-Ei Manual Manual (8 ...
Show more
See More
May 18, 2019 . Mesure de la durée de pulses d'un oscillateur AMPLITUDE SYSTEMS femto seconde.J'utilise un auto corrélateur Femtochrome FR103XL et un oscilloscope TEKTRONI...
Show more
See More
This manual provides information regarding the operation and maintenance of the Evolution II and Evolution X laser systems.
Show more
See More
Femtochrome FR-103MN Instruction Manual Instruction manual (30 pages) Mastech ms6231 Operator's Manual Operator's manual (21 pages) Vaisala HUMICAP HM70 User Manual Operation & user’s manual (72 pages)
Show more
See More
Femtochrome FR-103MN Instruction Manual Instruction manual (30 pages) Procentec ComBricks HE+ User Manual Operation & user’s manual (104 pages) Mettler Toledo DM40 Installation Information Installation information (32 pages)
Show more
See More
Pulse measurement equipment is now easier to use than ever before, with many devices offering easy-to-align solutions and plug-and-play computer operation, reports Neil Savage.
Show more
See More
Femtochrome FR-103MN Instruction Manual Instruction manual (30 pages) TESTO 330 Update Manual Update manual (8 pages) Tenma ST-95 User Manual Operation & user’s manual (4 pages)
Show more
See More
The controls for the delay arm enable a full scan range of 50 fs to 10 ps (i.e., ±25 fs to ±5 ps), and a micrometer tunes the detector's position for maximum signal. Detailed usage recommendations and examples are available in the manual. Setup Details
Show more
See More
Femtochrome FR-103XL Autocorrelator, Serial# 1021, To Include: Carrying Case, Manual, Located in Fremont, CA
Show more
See More
Use the "BEA" option. See "CODE V Generalized Beam Propagation and Coupling Efficiency Reference Manual" P1 onwards. The example on P10 includes a nice plot. 2. level 1. Claclink520. · 1y. You can set your ray density to be gaussian. I'm a zemax user, haven't used code v in a while.
Show more
See More
Page 30 , Femtochrome shall in no way be liable for damages consequential or incidental to defects in any of the products, for injuries resulting from its use, or for any other cause. This limited warranty constitutes the full understanding of Femtochrome and the buyer, and no...
Alignment Procedure The standard optical schematic of the FR-103MN is sketched in Figures 2 and 3. [When /FA (CC) Option is included, the alternate beam configuration described in section 4.a is applied. In this case, the delayed and fixed beams described below are reversed.
The precompensation setup is placed between the input laser beam and the FSAC, as shown in the diagram to the lower left. We simulated the effect of this setup on the measurement results of 15 fs pulses produced by an OCTAVIUS-85M (previous generation) femtosecond laser.
Interferometric Option (/IO) 1.The FR-103 is aligned for the standard noncollinear (background free autocorrelation) operation, with the retroreflecting comer mirror in its proper position on the translation stage. 2.The comer-mirror is then removed and the Interferometric Option is mounted on the T-stage, 广... Page 21 4c.
Page 10 The basic properties of the FR-103MN can be summarized as follows: Scan Range: >7 5 psec Resolution9: <5 fsec Delay Calibration Factor (T/t): 12.5 psec/msec ( 10Hz). The exact value of this factor has a weak dependence on the position of the pulse peak within the delay window (scan range). 3b.
Page 5 An optional A/D board installed in the unit and its software (Computer Data Acquisition (/CDA)), provides an interface (RS232) of the FR-103MN with a PC, resulting in a complete pulsewidth monitoring system. Alternatively, the N GA option renders the unit completely self-contained in a single package including a color TFT display.
Low Rep Rate Option (/LRR) The /LRR option renders the FR-103 to be operable with any pulse repetition rate (>4Hz).