Determine the Maximum and Recommended Spacings between Jetvent Fans for Different Levels of Fan Thrust These spacing distances are guidelines for fans placed in series. When the Recommended Fan Spacing is used, air …
Show more
See More
Introducing Jetvent Fans. Jetvent Fans’ energy-efficient ventilation system dynamically adjusts the ventilation rate according to the CO or NO 2 pollutant levels, or temperature in the space. A new step forward in garage induction …
Show more
See More
The JetVent Control Center offers a complete, standalone garage ventilation management control system that generates significant energy-savings versus traditional, ducted systems, and impulse ventilation systems. The pre-configured Digital JetVent Control Center responds to varying levels of pollutants, as reported by the sensors, and varies the operating speed of the fan (s), and …
Show more
See More
Practical Design. The low-profile design of these induction fans can result in significant savings in excavation and construction costs. Jetvent Fans are engineered to perform when mounted at the ceiling in-between support beams. This height savings can be the critical difference in providing ventilation for parking garages.
Show more
See More
Determine the Maximum and Recommended Spacings between Jetvent Fans for Different Levels of Fan Thrust These spacing distances are guidelines for fans placed in series. When the Recommended Fan Spacing is used, airspeed in most of the in most of the ventilated areas should be greater than 200 feet/min. CFD analysis will determine whether this is achieved in a …
Show more
See More
Product Overview. Jetvent Fans Control Center is designed as a complete stand-alone garage ventilation management control system that generates significant energy savings. The pre-configured Control Center responds to varying levels of pollutants, as reported by the sensors, and varies the operating speed of the fans.
Show more
See More
It contains information on how the technology works, examples of system layouts and applications, as well as full specifications for the entire range of Fantech Jetvent Fans. Also included is a step-by-step guide that takes the reader from the initial car park geometry assessment and design phases through to the installation, commissioning and ...
Show more
See More
JetVent Design parameters; Based on 5N per 100m 2 floor area, minimum total fan thrust = car park floor area x 5N/100m 2 = 1920m 2 x 5N/100m 2 = 96N ; Minimum thrust criteria can be achieved with 4 x JIU-CPCEC-SD fans on preset speed (operating thrust 28.4N), total fan thrust = 28.4N x 4= 113.6N.
Show more
See More
Call or Click today! Call JetVent® Fans. 855-JET-VENT (855-538-8368) Email Our Engineers. [email protected].
Show more
See More
Jet Fans are here. Although Jet Fans are slowly being adopted in North America through upgraded codes, Jet Fans have been globally accepted as a cost-effective alternative to traditional ducted parking garage ventilation for years. Soler & Palau has been investing in Jet Fan technology since the inception of the Jet Fan market globally.
Show more
See More
JetVent Air Mover Designed to provide air movement in large enclosed areas such as warehouses and recreation facilities. Suspended from the ceiling, it aids the natural cooling process of the human body at floor level and creates a fresher environment that is more comfortable to be in. Features
Show more
See More
Welcome to Jetvent, Irelands leading ductwork cleaning and air hygiene specialists. Environmentally-friendly and cost-efficient. All work carried out to highest recognised industry standards. Ductwork Cleaning and Air Hygiene Specialists. Jetvent is one of the longest established specialists in duct cleaning services. With our head office in ...
Show more
See More
Dynamic management of the ventilation system based on actual pollutant levels generates significant energy savings. The ventilation system runs dramatically less, at lower speeds, while safe ventilation levels are maintained. A Jetvent Fans ventilation system can be designed for virtually any garage.
The JetVent Control Center communicates with Jetvent Fans, sensors, detectors, and supply and exhaust fans, to dynamically control ventilation according to pollutant, smoke, or temperature levels in the space.
The ventilation system layout should complement the natural air path from supply to exhaust points. To make the system more effective, position Jetvent Fans in-line with supporting ceiling beams. If this is not possible, the system becomes less effective and more fans may be needed.
If height restrictions do not drive fan selection, using fewer, higher-rated Jetvent Fans generally makes the system more cost-effective than using more, lower-rated fans. However, to ventilate garages that are irregularly shaped, selecting more fans with smaller thrust ratings may be more effective.
The following steps are sufficient to create an initial ventilation system design. A Computational Fluid Dynamics (CFD) analysis is often required to prove and further refine the design. Fans may need to be re-orientated, or in some cases, added or removed. A ventilation system can be tailored to suit virtually any car park.
As previously mentioned, NOVENCO has played a leading role in the development of car park ventilation systems. The following provides a brief summary of the benefits to be achieved from using jet ventilation in car parking facilities: There is no need for space-consuming ducts in the car park, thus allowing the ceiling to be lower.
In big, open garages—particularly where supply and exhaust outlets are a large distance apart—Jetvent Fans can be used to reinforce the natural, directional airflow, boosting the volume of fresh air that ventilates the garage.
The effective working area of the jet fans depends on the type and function of the ventilation system. Jet fans are placed at strategic positions to ensure air movement and mixing throughout the car park.