The pre-configured Digital JetVent Control Center responds to varying levels of pollutants, as reported by the sensors, and varies the operating speed of the fan (s), and therefore the ventilation rate, by zone. This controller can also vary the speed of supply and exhaust fans and integrate their operation with overall ventilation requirements ...
Show more
See More
Introducing Jetvent Fans. Jetvent Fans’ energy-efficient ventilation system dynamically adjusts the ventilation rate according to the CO or NO 2 pollutant levels, or temperature in the space. A new step forward in garage induction ventilation systems, Jetvent Fans combine EC fan motors’ advanced technology, digital controls, and integrated sensors to deliver the ultimate in energy …
Show more
See More
Determine the Maximum and Recommended Spacings between Jetvent Fans for Different Levels of Fan Thrust These spacing distances are guidelines for fans placed in series. When the Recommended Fan Spacing is used, air speed in most of the in most of the ventilated areas should be greater than 200 feet/min. CFD analysis will determine whether this is achieved in a …
Show more
See More
The Control System for Jetvent Fans. The JetVent Control Center communicates with Jetvent Fans, sensors, detectors, and supply and exhaust fans, to dynamically control ventilation according to pollutant, smoke, or temperature levels in the space. This Control Center offers significant energy savings through comprehensive ventilation management — it costs less to …
Show more
See More
The JetVent Fan system utilizes the latest in EC motor technology with integrated speed control and connected sensors. The many advantages of Induction Ventilation Systems with Jetvent Fans is driving a rapid expansion of installations throughout Europe, Asia, Australia and the United States. Practical Design
Show more
See More
JetVent Design parameters; Based on 5N per 100m 2 floor area, minimum total fan thrust = car park floor area x 5N/100m 2 = 1920m 2 x 5N/100m 2 = 96N ; Minimum thrust criteria can be achieved with 4 x JIU-CPCEC-SD fans on preset speed (operating thrust 28.4N), total fan thrust = 28.4N x 4= 113.6N.
Show more
See More
Axial and Centrifugal fans for both general ventilation and emergency situations Our JetVent range includes induction and impulse ventilation models developed to operate as both general ventilation and for once-only, emergency extract mode …
Show more
See More
Call or Click today! Call JetVent® Fans. 855-JET-VENT (855-538-8368) Email Our Engineers. [email protected].
Show more
See More
JetVent axial fan . View Product . Roof Mounted Fans . Previous Category Roof Mounted Fans ... We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. Read more in our Cookie Policy. By clicking “Accept All”, you consent to the use of ALL the cookies.
Show more
See More
Dynamic management of the ventilation system based on actual pollutant levels generates significant energy savings. The ventilation system runs dramatically less, at lower speeds, while safe ventilation levels are maintained. A Jetvent Fans ventilation system can be designed for virtually any garage.
The JetVent Control Center communicates with Jetvent Fans, sensors, detectors, and supply and exhaust fans, to dynamically control ventilation according to pollutant, smoke, or temperature levels in the space.
In big, open garages—particularly where supply and exhaust outlets are a large distance apart—Jetvent Fans can be used to reinforce the natural, directional airflow, boosting the volume of fresh air that ventilates the garage.
Aviator controls should be placed in the Mechanical Services Switchboard enclosure. The RS485 ComLink line must start at the controller and then daisy chain to all the Jetvent Fans and Drives. The last connection must have an End-of-Line resistor.