Jockey Pump Requirements & Sizing - NFPA 20 - Fire

Oct 13, 2018 . A fire pump with rated capacity of 1500 gpm. Then the Jockey pump flow rate is 1500 gpm * 1% = 15 gpm. Jockey Pump Head: Pressure of Jockey pump shall be greater …

Show more

See More

Jockey - Technical Specifications - IMDb

Jockey (2021) on IMDb: Movies, TV, Celebs, and more... Oscars Best Picture Winners Best Picture Winners Emmys STARmeter Awards San Diego Comic-Con New York Comic-Con …
Runtime: 1 hr 34 min (94 min)

Show more

See More

Jockey pump in fire system - Grundfos

A Jockey pump is a small pump connected to a fire sprinkler system to maintain pressure in the sprinkler pipes. This is to ensure that if a fire-sprinkler is activated, there will be a pressure …

Show more

See More

Disc Jockey : Job Description, Duties and Requirements

Essential Information Disc Jockeys, also known as DJs, broadcast music over radio stations. They must ensure that commercials, interviews and commentary are delivered …

Show more

See More

Jockey Pumps AC Fire Pump

Jockey pumps or sprinkler system pressure maintenance pumps are a low cost yet essential component of a fire pump sprinkler system. Typically the Jockey pump is sized to 1% of the …

Show more

See More

Jockey India Official Site: Clothing Mankind Since 1876

Jockey India. Umiya Business Bay-Tower-1, 7th Floor, Cessna Business Park, Kadubeesanahalli, Varthur Hobli, Bengaluru 560103. Phone: 1860-4191913 / 1860-425-3333.
specification

Show more

See More

What is a Jockey Pump? - Info Bloom

Feb 13, 2022 . Dakota Davis Date: February 13, 2022 A Jockey pump works together with a fire pump as park of an indoor sprinkler system to put out fires.. A Jockey pump, or a pressure …
specification

Show more

See More

What Are Jockey Pumps and How Do They Work ... - Flow

Aug 29, 2016 . A Jockey pump, also known as a pressure-maintenance pump, is a small apparatus that works together with a fire pump as part of a fire-protection sprinkler system. It is …
specification

Show more

See More

TJ Series Yard Trucks Yard Jockeys - Capacity Trucks

THE ORIGINAL “TRAILER Jockey KNOWN WORLD-WIDE. Known as the “Original Trailer Jockey,” the TJ Series has evolved into three reliable models of yard Jockey trucks: the TJ …

Show more

See More

XTJL Jockey Lite Pump Controllers Models or technical

All Jockey Lite pump controllers are wired with a 120V control power transformer as standard. Dual Setting Pressure Switch A dual setting 15-290 PSI pressure switch is used to sense a …

Show more

See More

Kirloskar Fire Jockey Pump, Max Flow Rate: 180 Lpm - 300

Kirloskar Fire Jockey Pump, Max Flow Rate: 180 Lpm - 300 Lpm. हेड 40 - 160 मीटर फायर जॉकी पंप, अधिकतम फ्लो रेट: 180 - 300 एलपीएम. ₹ 58,000 Get Latest Price. Product …

Show more

See More

Frequently Asked Questions

  • What are the general requirements of jockey pump?

    General requirements of Jockey Pump: Jockey pump is preferred to be of centrifugal type pumps. Jockey pump shall be approved but shall not be required to be listed. The controller for a Jockey pump shall be listed but shall not be required to be listed for fire pump service. The Jockey pump shall not be required to have alternate or standby power.

  • What is a jockey pump?

    A pump designed to maintain the pressure on the fire protection system between preset limits when the system is not flowing water. The controller for a Jockey pump shall be listed but shall not be required to be listed for fire pump service.

  • What is the size of the sensing line of a jockey pump?

    Jockey pump shall have its own individual pressure sensing line (15 mm) nominal size made between its discharge check & isolation valve. For more information about sensing line, click here. The Jockey pump should be sized to provide a flow less than a single fire sprinkler.

  • Are all capacity yard jockeys off-road or dot?

    All Capacity yard Jockey models can be off-road or DOT, depending on your needs, as well as with your choice of features. Choose the right TJ model for you!

  • What should be the pressure of jockey pump in fire pump?

    Pressure of Jockey pump shall be greater than the pressure of main fire pump by minimum of 10 psi to avoid false starting of main fire pump. For more information about setting of fire pumps, click here.

  • What is the NFPA 20 requirement for a fire pump?

    Chapter 6 of NFPA 20 requires that the fire pump be powered by a reliable power source or by two or more independent sources. According to Annex A of NFPA 20, a reliable power source complies with 9.2.3 and has not:

  • How do you size a jockey pump for underground piping?

    A rule of thumb for sizing Jockey pump supplying underground piping is to use 1% of the fire pump rated capacity. A fire pump with rated capacity of 1500 gpm. Then the Jockey pump flow rate is 1500 gpm * 1% = 15 gpm.

  • What is a jockey pump?

    A pump designed to maintain the pressure on the fire protection system between preset limits when the system is not flowing water. The controller for a Jockey pump shall be listed but shall not be required to be listed for fire pump service.