K-weigh Design Guide

Listing Results K-weigh Design Guide

About 19 results and 8 answers.

Lightweight Steel Framing Architectural Design Guide

drywall versus 150 mm normal weight masonry back-up for a typical brick veneer wall. Stud = 0.29 kN/m2 Concrete block = 1.68 kN/m2 Compare the weight of steel stud with exterior wall insulation and finish system versus 100 mm precast concrete. Stud = 0.38 kN/m2 Precast = 2.39 kN/m2 In panelized construction, low weight assemblies cost

Show more

See More

Fuji K-Series Tangle Free Guides Angler's Resource

Fuji's new K-Series Guides provide tangle free performance with braided line. Three key factors, listed below, are attributed to this guide's patent pending performance. 1) The Frame: First, the frames on these guides are wide flaring out from the base just beyond the diameter of the ring to direct loops and tangles accumulating around the ...

Show more

See More

Frequently Asked Questions

  • What are the different types of vehicle weights?

    GROSS VEHICLE WEIGHT : The weight of a vehicle and its load. TRAIN WEIGHT : The weight of a vehicle, a trailer and its load. PLATED WEIGHT : Either the design weight limit given on a manufacturer’s plate or the legal weight limit given on the Department’s plate. TRAILER : Any vehicle drawn by a motor vehicle.

  • How do you determine the k value of a slab?

    If there are no adverse soil conditions, the design and analysis of a slab on grade requires only the determination of the strength of the sub-grade in terms of k. The only method to directly measure the k value is by a plate loading test taken on the compacted sub-grade (or sub-base, if used).

  • How much does a KCS joist weigh?

    joist to a KCS joist selected to carry the same loads: Determining the shear and moment envelopes we find that (Mmax = 1077 in. kips and the Max. Shear = 7324 lbs.) the KCS selection would be a 26KCS4 (see KCS table on page 77). The KCS joist weighs 16.5 lbs. per foot.

  • Which k value should be used in table 5-3b?

    • It should be noted that the k value of the sub-grade, rather than the k value on top of the sub-base (if there is one), is used in Tables 5-3b and 5-4b. This is appropriate for distributed loads covering large areas, while the use of the k-value on the top of the sub-base is appropriate for concentrated loads.

  • Is New Millennium Building Systems liable for the accuracy of the data?

    Although the data shown is believed to be accurate, New Millennium Building Systems does not assume any liability or obligation of any kind or nature arising from or related to the data provided herein and/or its use.

  • Where can I find the New Millennium Building Systems special profile catalog?

    the New Millennium Building Systems Special Profile Catalog on our web site at www.newmill.com. PARALLEL CHORD SINGLE PITCHED TOP CHORD DOUBLE PITCHED TOP CHORD

  • Is new millennium a quality company?

    QUALITY ASSURANCE New Millennium is a Steel Joist Institute (SJI) member company, fully certified to manufacture K, LH and DLH-Series Steel Joists, and Joist Girders. New Millennium is also a Steel Deck Institute (SDI) member company, fully certified to manufacture roof deck, form deck, and composite floor deck.

  • Why choose new millennium for steel package design?

    To further simplify and accelerate the steel package design process, New Millennium has packed the power of our specification catalogs into advanced web and mobile applications. Built upon our expertise in steel joist and metal deck engineering, and backed by our database of load and weight tables, this toolset will prove

Have feedback?

If you have any questions, please do not hesitate to ask us.