Lutron Qsn

Listing Results Lutron Qsn

About 18 results and 3 answers.

Lutron Energi Savr Node Solutions Model Numbers

98 rows . Lutron’s NEW facility management tool empowers you to manage your building from anywhere. Easily monitor, control and optimize a Lutron control system from any tablet, PC or smartphone. Each feature is designed around what is most important to you – how well your building is working. ... QSN-4T16-S: Energi Savr Node with Softswitch, 120 V ...

Show more

See More

Lutron - QSN-4S16-S, Radio Frequency Lighting Control

Four Occupancy Sensor Inputs for Automated Control of Lights in 4 Zones. For help with Energi Savr Node from Lutron Also known as: 027557871372, Energi Savr, LUTQSN4S16S, Lutron, QSN-4S16-S, Radio Frequency Lighting Control Systems, Room Controllers & Accessories - Wireless, Lighting Control Systems - Wireless, Lighting, Lighting Controls

Show more

See More

Lutron - QSN-4T20-S, Radio Frequency Lighting Control

For help with LUT QSN-4T20-S 0-10V CNTRLR 4ZONE 2 from Lutron Also known as: 784276091442, Energi Savr, LUTQSN4T20S, Lutron, QSN-4T20-S, Radio Frequency Lighting Control Systems, Room Controllers & Accessories - Wireless, Lighting Control Systems - Wireless, Lighting, Lighting Controls Associated (0) Substitutes (0) Others Also Bought (2)

Show more

See More

LUTRON QSN2 Energi Savr Node for 0–10 V- Energi Savr Node

Lutron QSN2 Energi Savr Node with Softswitch User Guide Energi Savr Node for 0–10 V Energi Savr Node with Softswitch The Energi Savr Node (ESN) family is a group of modular products for the control of lighting, receptacles, and other loads. This document describes the following products:

Show more

See More

Lutron QSN Softswitch Type 1 Enclosure 13" x 9" x 3

This item was n ever used or installed, but circuit board was pulled out. Enclosure only.

Show more

See More

Lutron QSN-4S16-S 120/277V 4CTS SoftSwitch Energi SavR

Lutron QSN-4S16-S 120/277V 4CTS SoftSwitch Energi SavR Node Motion Sensor Visit the Lutron Store 1 rating Currently unavailable. We don't know when or if this item will be back in stock. 120 - 277 V 50/60 Hz 500mA 4 Softswitch Circuits NEC Class 2 QS Link › See more product details Customers also viewed these products Page 1 of 1 Start over

Show more

See More

Lutron QSN-4T16 Energi Savr Node Manual Programming - YouTube

Paul Rudalavage from Synergy Electrical Sales demonstrates how to set up wired occupancy sensor, daylight sensor, and wired pico switch connected directly to...

Show more

See More

Lutron ESN QSN-4T16-S Panel Basics - YouTube

Paul Rudalavage from Synergy Electrical Sales shows the basics of the Lutron Energi Savr Node Panel for 0-10 volt dimming.

Show more

See More

Ceiling Sensors Lutron

Ceiling Sensors. Lutron offers a variety of occupancy/vacancy sensors so you’ll be able to choose the sensor that best fits your needs.

Show more

See More

ENERGI SAVR NODE™ INTEGRATION DEVICE, MULTIPLE INPUTS

Powers up to 2 EcoSystem Digital Links (QSN-2ECO-S) Easy system programming with an intuitive application for Apple iPhone or iPod touch mobile digital devices (required for non-Quantum® systems) Expand the number of sensors and controls using the QS Sensor Module (QSM) or sensors connections on EcoSystem ballasts and modules

Show more

See More

LUTRON Energi Savr Node with EcoSystem Installation Guide

Contents hide 1 Lutron Energi Savr Node with EcoSystem Install Guide 1.1 1 Mounting 1.2 2 Control Power Wiring 1.3 3 EcoSystem Link Wiring 1.4 4 QS Link Wiring (IEC PELV/NECR Class 2) 1.5 5 Contact Closure Input 1.6 6 LED Diagnostic Indicators 1.7 7 Verify Lights 1.8 8 Programming 1.9 Customer Assistance 1.10 Limited […]

Show more

See More

Lutron EcoSystem Digital Link QSN-1ECO-S Energi Savr Node

Lutron EcoSystem Digital Link QSN-1ECO-S Energi Savr Node 50/60 Hz 500 mA Visit the Lutron Store Currently unavailable. We don't know when or if this item will be back in stock. EcoSystem Energi Savr Node units are powered by line voltage (Hot and Neutral). 120/277V 50/60 Hz 500mA Enlace Digital 64 EcoSystem Device per link

Show more

See More

Connecting Radiora + grafik eye + Qsn-1eco-s

Hi,Through a grafik eye, I can activate the scenes of a qsn-1eco.Through RadioRA 2, I can activate the scenes (and zones) of a Grafik Eye.So, by means of the Lutron Home app I could activate the local scenes of the grafik and also the scenes of qsn?

Show more

See More

Lutron QSN-4A5-S Crescent Electric Supply Company

Lutron QSN-4A5-S Sign in or register to view your pricing and inventory. QSN-4A5-S Lutron PRO LED+ PHASE ADAPTIVE FIXTURE CONTROLLER Availability: Generally ships in 7-10 business days. Your Price $972.2200 / each $972.22 / Add to Cart Add To My List Product Details QSN-4A5-S QSN-4A5-S Lutron PRO LED+ PHASE ADAPTIVE FIXTURE CONTROLLER

Show more

See More

Frequently Asked Questions

  • How many Lutron daylight sensors can be assigned to a QSM?

    • Alternatively, up to four sensors (Lutron Wired Daylight Sensors or Radio Powr Savr Daylight Sensors) can be assigned when associated with a QSM. • The maximum number of Lutron daylight sensors (wired or wireless), either wired directly to the unit or indirectly (associated with a QSM) cannot exceed four.

  • How does the Lutron emergency contact closure input work?

    Emergency Contact Closure Input • By default, contact closure input from Lutron Emergency Lighting Interface (LUT-ELI-3PH), security, or fire alarm systems turns all zones on to full output when emergency state is detected. • Emergency contact closure input is normally closed (NC). The ESN unit is shipped with a jumper pre- installed.

  • How does Lutron occupancy sensor control a zone?

    • Use Lutron occupancy sensors to control one or more zones. • Use Lutron occupancy sensors in vacancy mode to automatically turn the lights off in an area after it becomes vacant. • Each zone can be programmed to automatically turn the lights on when occupied and turn the lights off when vacant.

Have feedback?