Apr 06, 2015 . Download this guide for details about the design elements that give our external cages the structural integrity demanded of your toughest level control applications. Magnetrol International 705 Enterprise Street Aurora, Illinois 60504 USA 1-800-624-8765 (U.S.) 1-630-969-4000 (outside U.S.) info@Magnetrol.com
Show more
See More
Magnetrol provides a level of expertise chemical processing facilities cannot find anywhere else. Magnetrol Services Chemical Processing with Their Most Difficult Application Challenges Level measurement plays a critical role in ensuring the safety and efficiency of chemical processes, including liquid extraction, vapor/liquid separation, and mixing and blending.
Show more
See More
Displacer controllers Apply Displacer controllers filter ; Displacer switches Apply Displacer switches filter ; Displacer transmitter Apply Displacer transmitter filter ; External cage switches Apply External cage switches filter ; Float level switches Apply Float level switches filter ; Guided wave radar Apply Guided wave radar filter ; Magnetic level indicators Apply Magnetic level ...
Show more
See More
The customer’s first call when performance matters. Products. Level control; Flow control; Volume control; Technologies; Applications
Show more
See More
Guided wave radar | Magnetrol Guided wave radar Micropower impulse radar combines time domain reflectometry, equivalent time sampling, and modern low power circuitry. This synthesis of technologies creates a high-speed Guided Wave Radar transmitter.
Show more
See More
The basis of magnet design is the B-H curve, or hysteresis loop, which characterizes each magnet material. This curve describes the cycling of a magnet in a closed circuit as it is brought to saturation, demagnetized, saturated in the opposite direction, and then demagnetized again under the influence of an external magnetic field..
Magnetrol
Show more
See More
The Magnetrol® external chamber is a self-contained cage designed for use with our top mounting level transmitters or switches. US en fr de IT ru Flanged Top External Caged Liquid Level Switches External cage type level switches are completely self contained units designed for side mounting to a tank or vessel with... US en fr de IT 中文 中文
Show more
See More
The basis of magnet design is the B-H curve, or hysteresis loop, which characterizes each magnet material. This curve describes the cycling of a magnet in a closed circuit as it is brought to saturation, demagnetized, saturated in the opposite direction, and then demagnetized again under the influence of an external magnetic field.
Magnetrol
Show more
See More
Inductors are devices that store and convert energy. A BH loop characterizes the useful region of operation of a magnetic component. When a gap is introduced into the core either discretely, as in a ferrite or distributed, as in a powder core, the ability of the device to store energy is greatly enhanced, from the region of 0.2 – 2.0 Oersteds for an ungapped core set to 100 – 1000 …
Magnetrol
Show more
See More
• AURORA chamber houses both the probe for Magnetrol ECLIPSE Guided Wave Radar transmitter and the float. The instrument transmits level data accurately and reliably. • Baffle plate design provides flawless guide for float. • For the most demanding high pressure/temperature liquid level applications.
Show more
See More
Magnetrol - Website Design I led the way for the full redesign of the Magnetrol International website. I designed the site and the information architecture, as well as managed the outsourced production company who built it. I also did product photography for many of the individual product images on the site. The Challenge: The old site was a
Show more
See More
Open the catalog to page 1 Guided Wave Radar Magnetrol® pioneered guided wave radar (GWR) by introducing the ECLIPSE® Model 705 two-wire, loop-powered transmitter for use in industrial liquid level applications. GWR offered users a powerful way to measure and control challenging media and process variations with unprecedented performance.
Show more
See More
Eclipse® Model 706 High Performance Guided Wave Radar Level Transmitter DESCRIPTION The new Eclipse® Model 706 High Performance Transmitter is a loop-powered, 24 VDC level transmitter that is based upon the proven and accepted technology of Guided Wave Radar (GWR). Encompassing a number of significant engineering accomplishments, this leading …
Show more
See More
Magnetrol. The future of advanced process control solutions is being powered by Magnetrol® – the level and flow expert and your preferred partner for operational efficiency, safety and performance. We design our products to the highest standards of excellence, ensuring remarkable reliability, intelligent functionality and value that far exceeds whole-life costs – for …
Show more
See More
Originally designed as an alternative to sight and gauge glass devices, the MLI is now commonly used in both new construction and plant expansion. Magnetic level indicators are precision engineered and manufactured to indicate liquid level accurately, reliably, and continuously. These units are completely sealed and require no periodic maintenance.
Show more
See More
As a result, floats ride on the liquid surface partially submerged and move the same distance the liquid level moves. Because of this, they are normally used for narrow level differential applications such as high level alarm or low level alarm. Magnetrol float level controls use a simple float and magnetic coupling action.
All float operated liquid level controls operate on the basic buoyancy principle which states "the buoyancy force action on an object is equal to the mass of liquid displaced by the object." As a result, floats ride on the liquid surface partially submerged and move the same distance the liquid level moves.
The chamber and magnetic float is available in a variety of materials and pressure ratings to accommodate the wide variety of complex process applications present in the world’s major industrial facilities. A change of level in the process tank corresponds to a similar change within the ATLAS chamber.
All our floats are fitted standard with a torriodal-magnet, because a float with a magnetic bar can loose there guidance/ indication rail by rapid movement inside the level gauge. As a result the magnetic level gauge will not work properly for a while.