Narcotrend

Listing Results Narcotrend

About 19 results and 7 answers.

NARCOTREND COMPACT M OPERATING

View and Download Narcotrend Compact M operating instructions manual online. Brain Function Monitor for the Operating Room and the Intensive Care Unit. Compact M medical equipment pdf manual download.

Show more

See More

The Narcotrend monitor

The Narcotrend algorithm is based on pattern recognition of the raw electroencephalogram (EEG) and classifies the EEG traces into different stages from A (awake) to F (increasing burst suppression down to electrical silence). The newest Narcotrend software version includes a dimensionless Narcotrend index from 100 (awake) to 0 (electrical silence).

Show more

See More

Narcotrend - EEG-Monitor für Narkose und Sedierung

This method (Narcotrend ®) allows for adjusting the dosages of anaesthetics to the patients' age, gender and general physical condition. During anaesthesia, this method helps to avoid EEG stages which are associated with an increased risk of awareness. On the other hand, overdosages can be avoided.

Show more

See More

The Narcotrend™ Monitor and the Electroencephalogram in

The Narcotrend™ (NCT) is a one-channel electroencephalogram (EEG) monitor of the level of sedation. It is based on a visual EEG scoring system, which was developed by Loomis and modified by Kugler, to yield a visual expert classification (VEC) scheme for differentiation of six levels of sedation (A–F), which are subdivided into 16 substages.

Show more

See More

Aplicación del Monitor Narcotrend® para Evaluar

The Narcotrend is a new electroencephalographic monitor designed to measure depth of anesthesia, based on a six-letter classification from A (awake) to F (increasing burst suppression) including ...

Show more

See More

Narcotrend® and Bispectral Index® Monitor Are Superior to

the Narcotrend®, a new monitor displaying a derived electroencephalographic parameter (Narcotrend®; monitortechnik, bad bramstedt, germany), automatically classifies the resting electroencephalogram into stages defined by kugler during the 1980s. 1,2 narcotic stages deescalate from the awake state (stage a) to isoelectric electroencephalogram …

Show more

See More

Gwenagen Medical Distributor Narcotrend TOFcuff/ Sales

Narcotrend MANUALS. Training on site/ on line. NEWS! now also in UK and Ireland! Narcotrend - depth of anaesthesia (hypnosis) brain function monitor (TOF)NMT Cuff - Quantitative NMT made easy! pEEG RECENT PAPERS. Library @Narcotrend HQ Germany . Call Leeds Office.

Show more

See More

Application of Bispectral Index® and Narcotrend® Index to

The Narcotrend® analysis integrates this scale using a multivariate statistical algorithm2that yields a value from 99 (awake) to 0, called the Narcotrend® index. Comparative studies between the BIS® and the Narcotrend® index have shown similar values with …

Show more

See More

Narcotrend ‘depth of anaesthesia’ monitor cannot reliably

Show more

See More

The Narcotrend monitor - ScienceDirect

Mar 01, 2006 . The Narcotrend algorithm is in part based on a classification of the sleep EEG and differentiates six EEG stages from A (awake) to F (burst suppression to down cortical silence), with 15 substages. In addition, a Narcotrend index is displayed with a range from 100 (awake) to 0 .

Show more

See More

Effects of circadian rhythm on Narcotrend index and target

Narcotrend is an electroencephalogram (EEG) monitor designed to measure the depth of anesthesia. The Narcotrend index, from 100 (awake) to 0 (electrical silence), indicates the different depths of anesthesia [ 5, 7 ]. However, it remains unclear whether the Narcotrend index under propofol TCI is impacted by circadian rhythms.

Show more

See More

Comparing Bispectral Index and Narcotrend monitors in

Show more

See More

Pentax EG-1690K Medical Equipment User manual manual PDF

Kanmed BB100-401F-073 Manual Manual (20 pages) Innova OBD2 Owner's Manual Owner's manual (32 pages) Narcotrend Compact M Operating Instructions Manual Operating instructions manual (47 pages) Nasco Life/form LF01025U Instruction Manual Instruction manual (4 pages)

Show more

See More

Dual-loop Target Controlled Infusion for Coadministration

Sep 07, 2016 . Dual-loop Target Controlled Infusion for Coadministration of Propofol and Remifentanil Guided by Narcotrend Index. The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. ... Placebo Comparator: manual

Show more

See More

NicoletOne™ EEG System Natus

NicoletOne EEG is a high quality, cost effective solution for the detection of various neurological disorders. The NicoletOne EEG system offers flexibility without compromising capability, delivering essential features for efficient performance, making it ideal for all clinical needs.

Show more

See More

BIS™ Brain Monitoring Products Medtronic

Advanced monitoring for improved outcomes. Bispectral Index™ (BIS™) technology was the first clinically proven and commercially available direct measure of the effects of anesthetics and sedatives on the brain. BIS™ technology enables medical professionals to reliably gauge the precise amount of anesthetic medication required by each ...

Show more

See More

Equipment failure of intravenous syringe pump detected by

The Narcotrend index of the patient returned to state of deep anesthesia following manual administration of the anesthetic medications. Following the surgery, the patient had an uneventful recovery, and did not present with evidence of awareness. Lessons:

Show more

See More

Aplicación del Monitor Narcotrend® para Evaluar la

May 01, 2013 . Application of a Narcotrend- assisted anaesthesia in-depth monitor in the microwave coagulation for liver cancer during total intravenous anaesthesia with propofol and fentanyl. Chin J Cancer., 29 (1) (2010), pp. 117-120. View Record in Scopus Google Scholar.

Show more

See More

Frequently Asked Questions

  • What do you need to know about the Narcotrend monitor?

    The Narcotrend monitor provides a vast amount of information: the actual Narcotrend stage and index, the trend (‘cerebrogram’), the raw EEG signal and a power spectrum and several derived EEG parameters.

  • What should the Narcotrend index be on a computer?

    In addition, a Narcotrend index is displayed with a range from 100 (awake) to 0 (Table 1). Narcotrend stages and index values 1 can be assigned as shown in Table 1.

  • How does the Narcotrend monitor calculate depth of anaesthesia?

    The Narcotrend™ (software version 4.0; MonitorTechnik, Bad Bramstedt, Germany) automatically quantifies depth of anaesthesia into stages using a six-letter system with a total of 14 substages. 11 18 20 This software version also provides a dimensionless numerical output from 100 (awake) to 0, called the Narcotrend index.

  • How is the Narcotrend method used in intensive care?

    In an interdisciplinary cooperation, a method for the automatic classification of EEGs recorded during anaesthesia or intensive care was developed. This method (Narcotrend ®) allows for adjusting the dosages of anaesthetics to the patients' age, gender and general physical condition.

  • How does the Narcotrend compact m monitor work?

    4.5 The Narcotrend-Compact M monitor automatically analyses the raw EEG data using spectral analysis to produce a number of parameters. Multivariate statistical methods using proprietary pattern recognition algorithms are then applied to these parameters to provide an automatically classified EEG.

  • How is the Narcotrend used in anaesthetics?

    This method (Narcotrend®) allows for adjusting the dosages of anaesthetics to the patients' age, gender and general physical condition. The Narcotrend (MonitorTechnik, Bad Bramstedt, Germany) is an EEG monitor designed to measure the depth of Hypnosis.

  • How does Narcotrend work on an electrocardiogram?

    The Narcotrend algorithm is based on pattern recognition of the raw electroencephalogram (EEG) and classifies the EEG traces into different stages from A (awake) to F (increasing burst suppression down to electrical silence). The raw EEG signal can be recorded by standard electrocardiogram electrodes for single- and double-channel registration.

Have feedback?

If you have any questions, please do not hesitate to ask us.