Onicon Incorporated is a leader in flow and energy measurement solutions and delivers comprehensive solutions for our customers’ needs. We specialize in HVAC flow and energy measurement solutions and providing our customers with the most accurate and reliable readings for their applications. We pride ourselves on the Onicon Difference, which ...
Show more
See More
Wiring Diagrams. Refer to Onicon’s Installation manuals for detailed wiring instructions. You may also contact Onicon’s technical service for system wiring diagrams that show the interconnection between the flow meter and any peripheral devices, such as …
Show more
See More
*Onicon defines the “design” flow rate as the maximum continuous flow expected by the application under normal operating conditions. The pressure drop for the Onicon design flow rates is ≤1.7 psi. System-40 Pressure Loss System-40 Pressure Loss Meter Size Process Connection Type Typical Design Flow 1% of Rate Flow Range 2% of Rate Flow Range
Show more
See More
Network & Software Information. Technical Notes. Wiring Diagrams. Case Studies. Conditions of Sale. Archives. The CAD / REVIT files provided represent typical installation layouts. Please contact Onicon’s sales office at (727) 447-6140 or e-mail us for assistance.
Show more
See More
We, at Onicon Incorporated, would like to thank you for purchasing our quality, U.S. made, Turbine Flow Meter. As our valued customer, our commitment to you is to provide fast reliable service and assistance, while continuing to offer you new products to meet your growing flow measurement needs. 1.1 PURPOSE OF THIS GUIDE
TURBINE FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 www.Onicon.com • sales@Onicon.com TURBINE FLOW METER Installation and Operation Guide 0721-6 / 1351804-16 FLOW AND ENERGY MEASUREMENT
Example:“F-1210” = Dual turbine, analog and frequency outputs 00Frequency Output (15 V pulse)For connection to Onicon display or BTU meter only. 10Analog Output (non-isolated) Provides 4-20 mA, 0-10 V and 0-5 V outputs. Most commonly used output type. Frequency output also available.
All Onicon insertion type meters can be installed and removed via a 1” or larger full port ball valve without stopping flow. The terms “Standard” and “Hot Tap” refer to the installation method of the isolation valve kit only.
11451 Belcher Road South, Largo FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • sales@Onicon.com Turbine Flow Meter Manual 09/15 - 0721-5 / 13518 Page 4 SECTION 1.0: INTRODUCTION We, at Onicon Incorporated, would like to thank you for purchasing our quality, U.S. made, Turbine Flow Meter.
TURBINE FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 www.Onicon.com • sales@Onicon.com TURBINE FLOW METER Installation and Operation Guide 0721-6 / 1351804-16 FLOW AND ENERGY MEASUREMENT
Measurements can become inaccurate when the product gets thicker or tinner. However, you can find flow meters designed to work in low viscosity or high. But some experts recommend applying turbine flow meters below 30 centipoise (cP) to keep your flow meter’s linearity from decreasing.
The Flowmetrics Tangential turbine flow meter is a unique volumetric device. This uses a dual orifice design to direct a stream of fluid tangent to a low mass/balanced rotor and a precision bearing to provide maximum sensitivity. Exceptionally reliable digital outputs.