Sep 17, 2013 . In order to ensure the basement space is habitable, insulation should be provided in external walls and floors. The insulation should have a reasonable thickness and be compatible with …
Show more
See More
Stairs to the basement should have a pitch of not more than 42° and have a headroom of not less than two metres, with suitable handrails and non-climbable balustrading with a gap of less …
Show more
See More
The Basement Parking space type refers to parking located below grade within an occupied building. As defined for the WBDG, the Level of Service (LOS) (refer to Architectural Graphic Standards, 10th Edition, page 106) of the Inside/Basement Parking is LOS B, indicating use by some unfamiliar users, moderate daily turnover, and medium percentage of small cars and light trucks; and requiring one-way aisles of 11'-0" straight-ways and 13'- 6" turns. See also WBDG Parking Structure.
Show more
See More
Jul 18, 2013 . Mechanical smoke extraction in a basement is generally achieved by providing ten air changes per hour. Additional design features also apply to ensure a level of redundancy in the …
Show more
See More
June 22, 2020. Neutral Basement Features a Sectional and Wood Accents. This expansive finished basement features lightly colored carpeting and recessed lighting throughout. A …
Show more
See More
Apartment Design Guide. 79 04 I Building. Apartment Design Guide Figure 4A.3 Horizontal louvres are most effective on north facing elevations and achieve summer shade and winter sun access Figure …
Show more
See More
4.4 Loss Prevention, Industrial Hygiene, and Personal Safety, 138 PART II DESIGN GUIDELINES FOR A NUMBER OF COMMONLY USED LABORATORIES 141 5 General or Analytical Chemistry …
Show more
See More
DIY BASEMENT FINISHING COURSE: https://eddie-case.mykajabi.com/store/ZNDvAVqL In this 4 part video series I will teach you exactly how to Design your new fin...
Show more
See More
The Safety Guidelines for Developments with Basement is prepared for the purpose of implementing higher Safety standards for basement development especially for deep excavation in soft marine clay in George Town. George Town has experienced some incidents of ground settlement issues induced by deep basement excavation works.
Additional Structural Requirements: Below grade extension of the building structure to accommodate basement parking is required. This involves additional excavation, structural frame, floor slabs above, sloped vehicle access ramps, and basement perimeter walls and partitions separating parking from other building enclosed areas.
Building a basement directly below or next to an existing building has become a popular means to extend a house. However, compared to a conventional above ground extension, basement construction is more complicated both in the design and preparation work needed, and in how the work needs to be carried out.
The standard does not apply to house foundation/basement excavations (including those that become trenches by definition when formwork, foundations or walls are constructed) when all of the following conditions are present: The house foundation/basement excavation is less than 71/
The basement’s walls and floors must be water-proof. The basement should not be accessed directly from the road. It should be accessed only from the main entrance or an alternative staircase that provides access to the building.
In case of damp sites, the surface of the ground and space between the walls has to be declared damp-proof, to the satisfaction of the authority. Building sites should be away from electric lines. Plus 0.3 metres for every additional 33,000 V or part thereof. Plus 0.3 metres for every additional 33,000 V or part thereof.
The Master Plan and land development rules and regulations of the authority decide the minimum size of the site. The NBC has guidelines for the entry, as well as exit points in buildings. An exit must be provided in every building, so as to permit safe escape of residents in times of fire or earthquakes, etc.
Guidelines for staircases in residential buildings 1 For group housing, where the floor area does not exceed 300 sq metres and the height of the building is not over 24... 2 In a residential low-rise building, the minimum width for the stairways is 0.9 metres. 3 For flats, hostels, group housing, guest houses, it is 1.25 metres. More ...