Ta Hydronics Sheet Product

Listing Results Ta Hydronics Sheet Product

About 19 results and 4 answers.

IMI TA

At IMI TA, we undersTAnd that to create a cost-efficient and balanced indoor climate, you need more than just products. Which is why we also provide you with hydronic tools and system knowledge through product trainings & seminars and expert support. We sTAnd by you through the entire project’s lifetime, to help solve your challenges and meet your needs.

Show more

See More

Instruments - TA-SCOPE IMI Hydronic


TA-SCOPE is a tough, effective balancing instrument for measuring and documenting of differential pressure, flow, temperature and power in hydronic systems. Robust, accurate and easy-to-use, TA-SCOPE delivers quicker, more cost-efficient balancing and enables rapid troubleshooting. TA-SCOPE links effortlessly to the HySelect PC software gaining the maximum benefit from recorded daTA and ena…

Show more

See More

Homepage IMI - IMI Hydronic

Valve entirely developed in-house by R&D teams to achieve best in class control performance mastering both energy meter technology and leveraging expertise on control valves. 1. Controls & Measures. Market-leading control performance, from 0.5% to 100% of qnom, thanks to great valve controllability and fast response time.

Show more

See More

Hydronic Balancing Valves – Hydronic Balancing Solutions

Feb 02, 2017 . TA Series 786, 787H & 78KH: DigiTAl hand wheel with 4 turns to open; Includes memory stop; TA Series 788 & 789: DigiTAl hand wheel with 8, 12 or 16 turns to open (depending on size); Includes memory stop; Rated from -4°F to +250°F | -20°C to +120°C TA Series 786 Solder End. Sizes from ½ - 2” | DN15 – DN50; 300 psi/2068 kPa/20.7 bar
Phone: (800) 742-5842

Show more

See More

Victaulic Manual Balancing Valves - Hydronic Balancing

TA Series 786, 787H & 78KH: DigiTAl hand wheel with 4 turns to open; Includes memory stop; TA Series 788 & 789: DigiTAl hand wheel with 8, 12 or 16 turns to open (depending on size); Includes memory stop; Rated from -4°F to +250°F | -20°C to +120°C . TA Series 786 Solder End. Sizes from ½ – 2” | DN15 – DN50; 300 psi/2068 kPa/20.7 bar

Show more

See More

IMI Hydronic Engineering Home

Homepage | IMI hydronic. Healthcare Solutions. Accurate indoor temperature and air quality are critical for the operation of healthcare facilities. In our eBook you can find out more about the solutions to most common HVAC challenges in healthcare facilities and how to …

Show more

See More

Differential pressure controllers - STAP IMI Hydronic

AMETAL ® is the dezincification resisTAnt alloy of IMI Hydronic Engineering. Marking: Body: TA, PN 16/150, DN, inch size and flow direction arrow. Bonnet: STAP, ΔpL 5-25, 10-40, 10-60 or 20-80. Connection: Female thread according to ISO 228, thread length according to ISO 7-1.

Show more

See More

TA Hydronics STAP 10-60 Kpa 20mm from Reece

Product Warranty: 12 Months: Learn about our Product Quality Guarantee. RFA - TA Hydronics STAP Download. Specification, Manuals & InsTAllation. Specification Sheet - TA Hydronics STAP Valves View. Specification Sheet - TA MDFO Flow Measuring Orifices View.

Show more

See More

TA Therm with Thermometer 35-80 Degree 20mm from Reece

Product code: 1006481. View Product Specifications. IMI TA HYDRONICS. This thermosTAtic valve for automatic balancing in domestic hot water. systems features a step-less temperature setting, saving energy. with reduced delay time for hot water. The shut-off function enables. straightforward maintenance while the temperature control feature.

Show more

See More

Case Study 11 – CUTS Institute for Regulation & Competition

TA Hydronics Switzerland AG Facts of the Case: The above named companies engaged in a cartel by coordinating prices in the Water Management Products sector in Germany and many other EU member sTAtes, which was discovered by the Commission in an unannounced inspection in December 2008 and April 2009, after receiving an immunity application from ...

Show more

See More

Extol Mechanical Joint Insulation Systems – Extol of Ohio

Specify Extol of Ohio, Inc Mechanical Joint Insulation Systems and Covers that Fit! Extol of Ohio, Inc., in business since 1962, has specialized in providing quality fabricated insulation systems for all types of applications. We use cellular, rigid materials to supply consTAnt thermal performance plus moisture and corrosion resisTAnce.

Show more

See More

Frequently Asked Questions

  • What are the sizes of the TA series 786 and 789 tools?

    Series 78K and TA Series 786, 787 – Red Polyamide plastic TA Series 788, 789: 2½ – 6" – Red Polyamide plastic 8 – 16" – Aluminum Optional Equipment: TA Series 786, 787: Drain kit-AmeTAl TA Series 786, 787: Insulation Kit-Polyurethane. Also available on TA Series 789 2½ – 6" sizes. Allen wrench sizes:

  • What is the difference between the TA series 786 and 787 valves?

    Series 78K and TA Series 786 and 787 valves have an AmeTAl®body. TA Series 788 and 789 balancing valves have ductile iron bodies and AmeTAl or ductile iron trim, depending on size. Test ports feature self-sealing construction for

  • Why Use ta-scope with hyselect?

    TA-SCOPE links effortlessly to the HySelect PC software gaining the maximum benefit from recorded daTA and enabling professional report writing and automatic software upgrades. TA-SCOPE is a tough, effective balancing instrument for measuring and documenting of differential pressure, flow, temperature and power in hydronic systems.

  • Where can I find information about hydronic engineering?

    Access the Knowledge Hub Our Knowledge Hub is the place where you will find all you need to know about the theory behind hydronic engineering and information about system diagnostics to help you get the most from our products. Our people are what makes IMI Hydronic Engineering GREAT!

Have feedback?

If you have any questions, please do not hesitate to ask us.