Service Manual 308012En, Ed.2 Rosemount Tank Radar Rex May 2013 Chapter 2 Safety Safety TankRadar REX equipment is often used in areas where flammable materials are handled and where an explosive atmosphere may be present. To protect both the plant and the staff, precautions must be taken to ensure that this atmosphere cannot be ignited.
Show more
See More
Rosemount TankRadar REX Chapter 1 Scope and Purpose of the Safety Manual Scope and Purpose of the Safety Manual The purpose of the safety manual is to document all the information, relating to TankRadar REX 3900 Series, which is required to enable the integration of TankRadar REX into a safetyrelated system, in compliance with the requirements of IEC …
Show more
See More
Rosemount Tank Radar AB REX User Manual. Download. Like. Full screen Standard. Page of 73 Go. Saab TankRadar L/2. 23. US Version. Seventh edition, June 1995. Installation Manual. 4.7. Description of the Independent Data Acquisition Unit. Warning: The DPS board inside the flameproof enclosure of the Indepen-
Show more
See More
TankRadar REX service manual. Use alphanumeric characters only – use a space for non alphanumeric characters. database contains 1 rosemount TankRadar REX rtg 3920 manuals ( available for free online viewing or downloading in pdf) : service manual. once the parts of the system have been installed, then use either. • remote readout.
Show more
See More
You can examine Rosemount TankRadar REX FCU 2160 Manuals and User Guides in PDF. View online or download 1 Manuals for Rosemount TankRadar REX FCU 2160. Besides, it’s possible to examine each page of the guide singly by using the scroll bar. This way you’ll save time on finding the necessary info.
Show more
See More
Seventh edition, June 1995 13 fInstallation Manual 3.1.3 Power Supply to the Radar Tank Gauge There is a switch on the Electronic Unit for setting of the power supply to 115 V or 230 V. As standard the switch is set to 230 V. Figure 3.3. MAINS Note: Do not turn the switch all the way around as it may damage the switch.
Show more
See More
You can examine Rosemount TankRadar REX 3900 Series Manuals and User Guides in PDF. View online or download 1 Manuals for Rosemount TankRadar REX 3900 Series. Besides, it’s possible to examine each page of the guide singly by using the scroll bar. This way you’ll save time on finding the necessary info.
Show more
See More
Description of the Slave Data Acquisition Unit, DAU 2100. The Slave DAU is intrinsically safe and is connected to the Radar. Tank Gauge on the same tank. It receives its power supply and. communicates via the Barrier Unit Card in the Radar Tank Gauge.
Show more
See More
Download Service manual of Rosemount TankRadar REX DAU 2100 Measuring Instruments for Free or View it Online on All-Guides.com. This version of Rosemount TankRadar REX DAU 2100 Manual compatible with such list of devices, as: TankRadar REX DAU 2100, TankRadar REX RDU 40, TankRadar REX RTG 3930, TankRadar REX RTG 3950, TankRadar REX RTG 3960
Show more
See More
Download Service manual of Rosemount TankRadar REX DAU 2100 Measuring Instruments for Free or View it Online on All-Guides.com. This version of Rosemount TankRadar REX DAU 2100 Manual compatible with such list of devices, as: TankRadar REX FBM 2180, TankRadar REX RDU 40, TankRadar REX RTG 3930, TankRadar REX RTG 3950, TankRadar REX RTG 3960
Show more
See More
Service Manual 308012En, Ed.2 Rosemount Tank Radar Rex May 2013 Chapter 2 Safety Safety TankRadar REX equipment is often used in areas where flammable materials are handled and where an explosive atmosphere may be present. To protect both the plant and the staff, precautions must be taken to ensure that this atmosphere cannot be ignited. Units.
The FCC certificate for Rosemount TankRadar REX requires that the tank is closed as far as emitted radio energy is concerned. Tanks with open manholes, external-floating-roof tanks without still-pipes etc. are not covered by the certificate. TOC-1
The Saab TankRadar REX system is configured and operated using the OPC compatible TankMaster software package. Its a user-friendly Human Machine Interface (HMI) software that gives the operator a good overview and quick access to any measured values.
Service Manual 308012En, Ed.2 Rosemount Tank Radar Rex May 2013 Chapter 3 Device Description 3.3.7 Database Registers The DAU’s database is stored in a nonvolatile memory (it will retain its contents even if the power is turned off), a serial EEPROM.
Service Manual 308012En, Ed.2 Rosemount Tank Radar Rex May 2013 Chapter 1 System Description System Description The TankRadar REX System is a monitoring and control system for tank level gauging. The system can interface various sensors, such as temperature and pressure sensors, for complete inventory control.
Rosemount TankRadar REX has been FCC certified under test conditions which assume a metallic tank. Installation on a non-metallic tank is not certified, and is not allowed.
The Radar Tank Gauge sends microwaves towards the surface of the product in the tank. The level is calculated based on the echo from the surface. TankRadar REX can measure the level of almost any product, including bitumen, crude oil, refined products, aggressive chemicals, LPG and LNG, etc.
It includes calibrations and adjustments in order to achieve high accuracy and reliability. The communi cation between various TRL/2 and Rex units is checked, and necessary backups of database files etc. are created. It also includes checking that the installations are done according to safety regulations.