User Manuals. TearLab has developed several resources that help you successfully integrate osmolarity testing into your practice. For access to these resources simply register for access. If you are already registered, please login. Test Cards IFU. User Manuals. Jul 29, 2020. Test Cards IFU. User Manuals.
Show more
See More
TearLab has developed several resources that help you successfully integrate osmolarity testing into your practice. For access to these resources simply register …
Show more
See More
TearLab Manuals and User Guides. All-Guides Database contains 1 TearLab Manuals (1 Devices) for Free Downloading (PDF).
Show more
See More
TearLab ® is intended to measure the osmolarity of human tears to aid in the diagnosis of dry eye disease in patients suspected of having dry eye disease, in conjunction with other methods of clinical evaluation. *TearLab is for professional in vitro diagnostic use only.
Show more
See More
Jul 26, 2016 . Step by Step demonstration on how to perform the TearLab test.
Show more
See More
Feb 27, 2017 . Daily quality system check to test the function of the TearLab reader and pens.
Show more
See More
TearLab® Osmolarity System. TearLab’s state-of-the-art lab on a chip technology measures Osmolarity (the salt content in the tears) by testing a small tear sample. We will test both eyes, and will then take the larger number of the two tests, to produce your osmolarity number. Your osmolarity number shows me the health and durability of the ...
Show more
See More
Cash position of $7.1 million as of December 31, 2019. -. Expanded the U.S. active device base to 4,834 and active accounts to 1,854 TearLab Osmolarity Systems. For the three months ended December 31, 2019, TearLab’s net revenues were $5.5 million, down …
Show more
See More
Normal osmolarity was defined as < 300 mOsm/L in both eyes and an inter-eye difference of < 8 mOsm/L. Values greater than 300 mOsm/kg is suggestive of dry eye. From 300 mOsm/L to 320 mOsm/L, is graded as mild; from 320 mOsm/L to 340 mOsm/L, is graded as moderate; and greater than 340 mOsm/L, is graded as severe.
Show more
See More
The manufacturer’s instruction manual provides reference data on tear osmolarity measured by I-Pen including a mean value of 300 mOsm/L and range of 275–316 mOsm/L for normal patients, and a ...
Show more
See More
The manufacturer’s instruction manual provides reference data on tear osmolarity measured by I-Pen including a mean value of 300 mOsm/L and range of 275–316 mOsm/L for normal patients, and a mean value of 327 mOsm/L for dry eye patients 12, 22.
Show more
See More
Sep 01, 2011 . The TearLab Corporation offers a device manual and staff and doctor training via teleconference and/or on-site. Supplementary online videos (www.TearLab.com) provide support as well, and the company offers additional training sessions as refresher courses on their website for existing staff and new employees.
Show more
See More
TearLab Corporation. The TearLab Osmolarity System is the first objective and quantitative test for diagnosing and managing dry eye disease. Empower your dry eye diagnosis and gain immediate ...
Show more
See More
TearLab. Updated July 8, 2021. Zippia gives an in-depth look into the details of TearLab, including salaries, political affiliations, employee data, and more, in order to inform job seekers about TearLab. The employee data is based on information from people who have self-reported their past or current employments at TearLab.
Show more
See More
Nov 30, 2017 . SAN DIEGO, Nov. 30, 2017 (GLOBE NEWSWIRE) -- TearLab Corporation (OTCQB:TEAR) (TSX:TLB) (“TearLab” or the “Company”), today announced that it is launching a registered direct offering to raise gross proceeds of approximately $3.0 million, prior to any placement agent commissions and other offering-related expenses. Subject to obtaining the Toronto Stock …
Show more
See More
To assess the NIBUT, the software asses the different segments and distortion in the reflected mires. A recent study reported that the pattern of tear break-up may suggest which layer of the tear film is primarily affected, such as aqueous tear layer/secretory mucins or surface epithelial layer/membrane-associated mucins.
Tear film instability is usually evaluated by a simple tear break-up time (BUT) test using a vital dye, fluorescein. Some of the newer imaging techniques offer non-invasive ways to measure BUT. Tear osmolarity can be directly measured using a point-of-care device in-office.
Tear film stability is measured automatically using a specific software through detection of break-up on the image reflected from the ocular surface, either a grid pattern or placido disk images. To assess the NIBUT, the software asses the different segments and distortion in the reflected mires.
Analytical Variability of the TearLab Osmolarity System The TearLab Osmolarity System has demonstrated the ability to measure nanoliter volumes of tear fluid with the same analytical performance as laboratory osmometers (Table 1). Precision and accuracy are a reflection of repeatability.
How it works. The TearLab Osmolarity Test Card, in conjunction with the TearLab Osmolarity System, provides a quick and simple method for determining tear osmolarity using nanoliter (nL) volumes of tear fluid collected directly from the eyelid margin. The Test Card is held by the Osmolarity Test Pen, for safe collection.
The TearLab Osmolarity System* is intended to measure the osmolarity of human tears to aid in the diagnosis of dry eye disease in patients suspected of having dry eye disease, in conjunction with other methods of clinical evaluation.
Tear osmolarity is informative when the results are abnormal or normal. An elevated reading, >300 mOsm/L, indicating loss of homeostasis.† OR, When the inter-eye difference is >8 mOsm/L, indicating instability of the tear film.† A symptomatic patient with normal tear osmolarity may not have dry eye.
Using patients selected from the general patient population, osmolarity was found to have 88% specificity, 75% sensitivity in mild/moderate disease and 95% sensitivity in severe disease at a diagnostic cutoff of 308 mOsms/L. Osmolarity values above 308 mOsms/L are therefore indicative of dry eye disease1.