Vernier products are designed specifically for education and held to high standards. How to Order. We offer several ways to place your order with us. Explore the options. 2021 Catalog. See what’s new for engaging the scientists and STEM educators of tomorrow …
Show more
See More
User Manual – Vernier User Manual Order Code: Download Manual PDF Contact Support Fill out our online support form or call us toll-free at 1-888-837-6437.
Show more
See More
www.Vernier.com/start/svis-pl Using the Product with Logger Pro Connect the sensor following the steps in the Getting Started section of this user manual. Select the Type of Data (or Units) You Want to Measure The default data type is absorbance. If you want to measure the absorbance of a solution, proceed directly to the Calibrate section below.
Show more
See More
Download Manual PDF The Vernier Colorimeter is used to determine the concentration of a solution by analyzing its color intensity. The cuvette slot is designed to accommodate most cuvettes with a 10 millimeter path length. The Colorimeter measures the amount of light transmitted through a sample at a user-selectable wavelength.
Show more
See More
Photogate User Manual Order Code: VPG-BTD Go to Product Page Download Manual PDF The Vernier Photogate is used for speed and acceleration measurements of objects passing through the gate. The object blocks an infrared beam as it passes. Motion data …
Show more
See More
pH Sensor User Manual – Vernier pH Sensor User Manual Order Code: PH-BTA Go to Product Page Download Manual PDF The pH Sensor can be used for any lab or demonstration that can be done with a traditional pH meter, including acid-base titrations, monitoring pH in an aquarium, and investigating the water quality of streams and lakes.
Show more
See More
www.Vernier.com/start/con-bta Using the Product Set the range switch on the sensor. Thoroughly rinse the lower section of the probe using distilled or deionized water. Connect the sensor following the steps in the Getting Started section of this user manual. When you are finished making measurements, rinse the electrode with distilled water.
Show more
See More
The users have to manually calculate both the scales (the main scale and the Vernier scale ). Vernier scale calculation, especially, is the contrasting thing when compared to reading those two types of caliper. Your eyes have to be careful when deciding which one the aligned line is. This is the core thing when you read Vernier caliper.
Show more
See More
The manual version has both an imperial and metric scale. Manually operated Vernier calipers can still be bought and remain popular because they are much cheaper than the digital version. Also, the digital version requires a small battery whereas the manual version does not need any power source. HOW TO READ A MEASUREMENT FROM THE SCALES
Show more
See More
Nov 25, 2008 . To use a Vernier caliper, start by twisting the locking screw counterclockwise to loosen it. Then, close the jaws of the instrument all the way so you start with your scales lined up at zero. Next, …
Show more
See More
The method to use a Vernier scale or caliper with zero error is to use the formula 'actual reading = main scale + Vernier scale − (zero error)' thus the actual reading is 19.00 + 0.54 − (0.10) = 19.44
Show more
See More
Vernier Caliper, High Precision Metal Vernier Caliper Manual Measuring Caliper Tools Micrometer Ruler for Measuring The Inner Diameter and Outer Diameter(6inch)
Show more
See More
The Vernier scale provides accuracy to the reading of the main scale by further dividing the lowest reading of the main scale into increments. In a metric caliper, the Vernier scale is divided into 50 increments each representing 0.02 mm. Thumb Screw: The thumb screw is …
Show more
See More
Colorimeter User Manual. The Vernier Colorimeter is used to determine the concentration of a solution by analyzing its color intensity. The cuvette slot is designed to accommodate most cuvettes with a 10 millimeter path length. The Colorimeter measures the amount of light transmitted through a sample at a user-selectable wavelength.
The example shown below is a manual caliper. Measurements are interpreted from the scale by the user. This is more difficult than using a digital Vernier caliper which has an LCD digital display on which the reading appears. The manual version has both an imperial and metric scale.
Note: Vernier products are designed for educational use. Our products are not designed nor are they recommended for any industrial, medical, or commercial process such as life support, patient diagnosis, control of a manufacturing process, or industrial testing of any kind. Choose a platform below to see its compatibility requirements.
The Vernier caliper is a smaller scale attached to the main scale and can move along the main scale as the jaws are opened or closed. The Vernier scale provides accuracy to the reading of the main scale by further dividing the lowest reading of the main scale into increments. In a metric caliper, the Vernier scale is divided into 50 increments ...
The example shown below is a manual caliper. Measurements are interpreted from the scale by the user. This is more difficult than using a digital Vernier caliper which has an LCD digital display on which the reading appears. The manual version has both an imperial and metric scale.
Designed for education and built to last, Vernier technology is durable, dependable, and affordable. Our sensors and software are supported by hands-on experiments and educator-focused technical support. Browse our robust STEM solutions to see how Vernier technology can help you.
Vernier warrants this product to be free from defects in materials and workmanship for a period of five years from the date of shipment to the customer. This warranty does not cover damage to the product caused by abuse or improper use. This warranty covers educational institutions only.