You can examine Wavelength References Clarity Series Manuals and User Guides in PDF. View online or download 1 Manuals for Wavelength References Clarity Series. Besides, it’s possible to examine each page of the guide singly by using the scroll bar. This way you’ll save time on …
Show more
See More
Consult your spectrophotometer's reference manual for the specification of your instrument's wavelength tolerance. This figure will be listed as a plus and minus (+/-) number in nanometers (nm). Add your instrument's wavelength tolerance to the confidence limit on the certificate supplied with the Didymium Wavelength Reference for your expected wavelength range.
Show more
See More
Show more
See More
MANUAL Mode MANUAL mode is intended to be used when a task is intolerant of the variations in the emission intensity and wavelength that occur during the re-locking procedure. The user may toggle between AUTO and MANUAL modes using a button on the front panel.
Show more
See More
This Anritsu MG9586A Wavelength Reference Light Source is used, and in excellent condition. Includes front panel cover plate. Specs: • Center wavelength: ~1547.5 nm • Half width: 138.0 nm • Total Output Power: -15.93 dBm Click here for spectrum of half-width output. Click here for …
Show more
See More
Wavelength reference cells are vacuum sealed with a concentration of certain gasses and vapors which have precicely defined absorbtion spectrums. These cells are commonly used in spectroscopic applications such as tunable diode laser calibration, stabilization of laser frequencies, and calibration of wavelength meters.
Show more
See More
SRMs 2514, 2515, 2517a and 2519a are fiber-connected molecular gas absorption cells with lines in the 1510 to 1630 nm region; SRMs 2518 and 2538 are devices with stable and known polarization mode dispersion-2518 simulates mode-coupled differential group delay (DGD) typical of optical fiber, whereas 2538 is a non-mode-coupled device exhibiting relatively wavelength-independent DGD typically …
Show more
See More
1 Installing the Variable Wavelength Detector 20 1100 Series Variable Wavelength Detector Reference Manual To disconnect the detector from line, unplug the power cord. The power supply still uses some power, even if the power switch at the front panel is turned off.
For contact information, go to Contact Us on http://www.thermofisher.com. Contacting Us Variable Wavelength Detectors (VC-D40, VF-D40) Operating Manual Page 3 Contacting Us Page 4 Variable Wavelength Detectors (VC-D40, VF-D40) Operating Manual
Holmium has been used as a wavelength reference for many years and like its liquid counterpart, the holmium glass filter produces characteristic peaks that make it suitable for use as a wavelength reference.
The DFB laser has a vacuum emission wavelength that intersects the P (13) absorption line, which is also referred to as a fringe. This makes the P (13) fringe a convenient wavelength reference for the LLD1530. The P (13) fringe is highlighted in red in Figure 1 and in Figure 2]
Wavelength References remains open during the COVID pandemic and does not foresee closures or significant delays at this time. Staffing has been reduced, additional cleaning and distancing policies are in place, and employees are working from home to the maximum extent possible.
The Thermo Scientific Dionex™ICS Series Variable Wavelength Detector (Dionex VWD) is a high-quality instrument designed for IC analysis applications requiring a UV-Vis detector and for LC analysis applications requiring an inert (PEEK™) flow path.
•Two light sources, a deuterium lamp for ultraviolet detection and a tungsten lamp for visible and near-infrared wavelength detection, provide a wavelength detection range from 190 to 900 nm. For details about the lamps and wavelength detection ranges, see Section 2.2.4.
The electronic version (i.e., PDF file) of the Dionex VWD operator’s manual contains numerous hypertext links that can take you to other locations within the file. These links include: •Table of contents entries