16 rows . Westinghouse Circuit breakers Manuals and User Guides PDF Preview and Download. Download ...
Show more
See More
IB 33-216. Type SAF-2 Operating Mechanism for Type F-122 and Type F-124 Oil Circuit Breakers. Category: F. Year1953. File Size889.14 Kb.
Show more
See More
Circuit breakers Westinghouse DBN-1016 Technical Manual Bemovable assembly 1600-ampebe fbame size standabdized dimensions (47 pages) Circuit breakers Westinghouse DB …
Show more
See More
Electrical Manuals for electrical equipment. TYPE DH DE-ION AIR CIRCUIT BREAKER 600A, 1200A, 2000A, 2500-5000V
Show more
See More
Dec 19, 2017 . DS-420 Manually Operated Circuit Breaker 151D062G05 DS-420 Power Operated Circuit Breaker 151D062G06 DS-632 B Manually Operated Circuit Breaker 151D062G07 DS-632 B Power Operated Circuit Breaker 151D062G08 DSL-206 Manually Operated Circuit Breaker 140D776G01 DSL-206 Power Operated Circuit Breaker 140D776G02
Show more
See More
Electrical Manuals for electrical equipment. TESTING OF AMPTECTOR, DIGITRIP RMS OR OPTIM TRIP UNITS USING TESTER STYLES 140D481G02R, 140D481G02RR, 140D481G03 OR 140D481G04 FOR DS, DSII, DSL AND DSLII CIRCUIT BREAKERS
Show more
See More
Jun 02, 2010 . Square D - FLUARC SF6 Circuit Breaker Type FC - Manual 9880-1 Allen Bradley - 1500-5.0 - Centerline Contact Cutler-Hammer - 2175A11G60 - Ampgard English Electric OB-50 Powell - IB-50000 - P-50000 Powl-Vac Powell IB-51000 - P-51000 Powl-Vac Toshiba 6F9A2 - VK Type Vacuum Circuit Breaker VK-6M32B2 Roller-Smith Type BD Air Circuit Breakers
Show more
See More
Westinghouse - Molded Case Circuit Breakers EHB2050 , Westinghouse / Cutler Hammer, AB DE-ION, type EHB, 2P, 1PH, 50A, 480V, [email protected] , standard interrupting capacity, 40°C, bolt-on, LI - Long-Time and Instantaneous trip functions and load side lug terminals, thermal magnetic, molded case circuit breakers; these breakers are now obsolete; however, we do still stock them
Show more
See More
RLE-800 Siemens 800A MO/DO LSIG Air Circuit Breaker Amperage 800 Voltage 600 Operation Manual Fixed Mount or Draw Out Draw Out Functions LSIG We have several of... LA-600 Allis-Chalmers 600A MO/DO LI Air Circuit Breaker (Parts Breaker) Amperage 600 Voltage 600 Operation Manual Fixed Mount or Draw Out Draw... DB-75 Westinghouse 3000A EO/DO LS Air Circuit Breaker Amperage …
Show more
See More
Westinghouse Amptector™ Trip The Westinghouse Amptector is a solid state device that provides adjustable over current tripping for Westinghouse Type OS low-voltage a-c power circuit breakers. Only one Amptector is required per breaker, and it receives all its energy from a set of sensors -one mounted on each pole of the breaker.
Descriptive Bulletin 32-650 Page 8 Westinghouse Westinghouse Amptector™ Trip The Westinghouse Amptector is a solid state device that provides adjustable over current tripping for Westinghouse Type OS low-voltage a-c power circuit breakers.
Bus sections are also isolated at a bus tie breaker. Enclosed wiring troughs are used through out the switchgear. Control circuit terminal blocks are mounted on the rear frame where they are readily accessible for purchaser's connections and inspection.
6 | Westinghouse Portable Power DANGER Never use the inverter in a location that is wet or damp. Never expose the inverter to rain, snow, water spray or standing water while in use. Protect the inverter from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.
Westinghouse Amptector™ Trip The Westinghouse Amptector is a solid state device that provides adjustable over current tripping for Westinghouse Type OS low-voltage a-c power circuit breakers. Only one Amptector is required per breaker, and it receives all its energy from a set of sensors -one mounted on each pole of the breaker.
ElectricalPartManuals . com Descriptive Bulletin 32-650 Page 8 Westinghouse Westinghouse Amptector™ Trip The Westinghouse Amptector is a solid state device that provides adjustable over current tripping for Westinghouse Type OS low-voltage a-c power circuit breakers.
All-Guides Database contains 936 Westinghouse Manuals (1573 Devices) for Free Downloading (PDF). Westinghouse Intercom System WHI-3S - One Piece Intercom Unit Installation and operation instructions manual (16 pages, 1.78 Mb)
Westinghouse Application For the control and protection of power cir cuits for fans, pumps, lighting and machines at 208, 240, 480 or 600 volts ac. Available for secondary unit substations through 2000 kva at 480 or 600 volts or 1000 kva at 208